This message only applies to parallel ATA and certain legacy serial ATA drives. The 3ware RAID controller then retries the failed command three times at the current UDMA transfer rate. Mine don't run hot. This message is posted when the result of the health test is below the fault threshold.

In this case, the controller is inoperable. 038h SO-DIMM not detected This AEN will be sent if there is no SODIMM memory connected to the controller. You may also see this message if the battery pack is plugged in while the computer is on. share|improve this answer answered Jun 27 '13 at 21:20 GioMac 3,4472929 ZFS performs integrity checks of the RAIDZ array, and it would have caught any bad sectors. Action: None required. 8041 Enclosure voltage over Event Type: Error Cause: Applies only to the 9690SA controller.

3ware Ecc Error Rebuild

Alas, it has not happened. Get 1:1 Help Now Advertise Here Enjoyed your answer? ECC error means an unrecoverable error while reading from this disk. TIME: Sat May 31 09:27:13 2003 MESSAGE: Drive sector ECC error corrected on port 1 on controller ID:0.

Contact your enclosure manufacturer for more information. 8026 Enclosure temp added Event Type: Information Cause: Applies only to the 9690SA controller. For information on replacing a fan, see your enclosure documentation or contact your enclosure manufacturer. 8002 Enclosure fan removed Event Type: Warning Cause: Applies only to the 9690SA controller. Action: None required. 8004 Enclosure fan unknown Event Type: Warning Cause: Applies only to the 9690SA controller. Hard Drive Ecc Error This AEN is posted when the result of the health test is below the fault threshold.

This indicates that the Battery Backup Unit must be replaced. 049h Battery temperature is normal The Battery Backup Unit measures and evaluates the battery pack temperature on a continuous basis. Ecc Error 3ware 9650 Not the answer you're looking for? Diese Liste war bis dato nur in der "3ware HTML Bookshelf" hinterlegt welche sich auf der 3ware Codeset CD befindet. http://blog.coffeebeans.at/archives/40 The enclosure power supply voltage is lower than the normal range.

The fan may not be seated correctly or may be malfunctioning. Tw_cli Ignoreecc The enclosure temperature is now back within the acceptable range. This was the last revision I believe. This may require specialized skills.

Ecc Error 3ware 9650

You change the failed disk and everything seems good as the disk starts recovery. http://titan.physx.u-szeged.hu/opt/3ware/3DM2/help/en/AEN_0026.html In this case, the controller is inoperable. 039h Buffer ECC error corrected This AEN will be sent when the controller has detected and corrected a memory ECC error. 03Ah Drive power 3ware Ecc Error Rebuild The parity data does not equal the user data. 3ware Degraded Drive Action: None required. 8021 Enclosure temp low Event Type: Information Cause: Applies only to the 9690SA controller.

If the measured battery capacity is less than 120 hours the recommended test interval is 4 weeks. 0055 Battery charging started Event Type: Information Cause: The Battery Backup Unit has started therefore you should replace p1 and rebuild the raid good luck 0 LVL 7 Overall: Level 7 Linux 7 Disaster Recovery 1 Message Author Comment by:martin_21102009-05-04 p0 failed, I already The 3ware RAID controller supports SMART monitoring, whereby the individual drives automatically monitor certain parametric information such as error rates and retry counts.This type of monitoring may be able to predict Contact your enclosure manufacturer for more information. 8044 Enclosure current normal Event Type: Information Cause: Applies only to the 9690SA controller. Tw_cli Start Rebuild

Comment Submit Your Comment By clicking you are agreeing to Experts Exchange's Terms of Use. Action: Allow the verification to complete. I've bought five 96147H6s via ebay. As far as sizes go, every 96147H6 SHOULD report the same number of sectors.

After detection of the drives, the 3ware RAID controller then uses an internal algorithm to logically connect drives that belong to the same array. Tw_cli Cheat Sheet Do I count up or down? Auslesen der SMART Werte.

So those two drives are in use in another fashion.

It is in fact rebuilding... I've only resorted to that to try to keep the array alive. To prevent unclean shutdowns, the user should always go through the normal shutdown procedure for the operating system in use and use an uninterruptible power supply (UPS) to prevent unclean shutdowns Tw_cli U Action: Replace the battery pack if warnings persist. 005D Battery health check failed Event Type: Error Cause: The Battery Backup Unit is not able to backup the 3ware RAID controller.

Light Bulb ReplacererAutoModeratorBotBustsolidbluJack of All Tradesbandman614Standalone SysAdminhighlord_foxBlinkenlights AdministratorVA_Network_NerdInfrastructure Architect & Cisco BigotLord_NShYHSystems Architectvitalyshpreperatabout moderation team »discussions in /r/sysadmin<>X· 24 comments If there's a tech skills shortage, why are so many computer graduates unemployed?79 points We recommend using 3DM, CLI or 3BM to check your settings, in case they were not able to be restored. 0040 Flash file system repaired Event Type: Information Cause: A corrupted This can be due to a failing power supply or an unreliable power source. Share this post Link to post Share on other sites sixthofmay 0 Member Member 0 221 posts Posted June 14, 2003 · Report post Tolyngee wrote: "Maxtor is very aware

Is the NHS wrong about passwords? Share this post Link to post Share on other sites honold 0 Member Member 0 6204 posts Posted June 13, 2003 · Report post that failure rate is very abnormal If the unit remains degraded, replace the missing or dead drives and initiate a rebuild. 0003 Controller error occurred Event Type: Error Cause: The 3ware RAID controller has encountered an internal Documents are in the WIKI.

Remove the BBU control module from the 3ware RAID controller and the battery module from the remote card. 3. The controller will attempt to correct the error by reading the back-up copy of the DCB. Action: None required. 0008 Unclean shutdown detected Event Type: Warning Cause: The 3ware RAID controller detected an unclean shutdown of the operating system, either from a power failure or improper shutdown The user should check that there is enough airflow around the Battery Backup Unit.

The enclosure temperature is below the enclosure manufacturer’s specified operating temperature. Turn off the computer and remove the 3ware RAID controller. 2. Verify = Media Scan RAID 0. permalinkembedsaveparentgive gold[–][deleted] 1 point2 points3 points 2 years ago(2 children)Welcome to why you don't do RAID 5 on huge arrays.